top of page
Description
Sequence valve, cartridge flange. Possible statically overload approx. 1.5 x p max.
Product Data
Article no.: 6918-2-02-04
Min. operating pressure: 16 bar
Max. operating pressure: 160 bar
Q: 20 l/min
Direction of flow: P-A
Ambient temperature: -40 - +80 °C
Viscosity: 10-500 cSt
DI-1 Seal Order No.: 570345
OR-1 O-ring Order No.: 570346
Weight: 150 g
Design
Steel housing, nitrided. Sealing nut galvanized. All functional components hardened and ground. Balls out of roller bearing steel.
Application
The pressure sequence valve is used in cases where another consumer is connected to the circuit after a set pressure has been reached. If several sequence valves are employed in the circuit, the pressure in this circuit always adjusts to the last pressure stage. For this type, the switching pressure remains largely constant, regardless of the outflow pressure on the outlet side.
Note
For disassembly of the pressure valve please release first SW 24, then SW 22. For assembly please use reverse sequence and observe max. seating torque. The pressure difference between P and A depends on the preload of the adjustment spring.